Example:
CALC:LIM:ACP:ACH 30DB, 30DB
Sets the relative limit value for the power in the lower and upper
adjacent channel to 30 dB below the channel power.
CALC:LIM:ACP:ACH:ABS -35DBM, -35DBM
Sets the absolute limit value for the power in the lower and
upper adjacent channel to -35 dBm.
CALC:LIM:ACP ON
Switches on globally the limit check for the channel/adjacent
channel measurement.
CALC:LIM:ACP:ACH:STAT ON
Switches on the check of the relative limit values for adjacent
channels.
CALC:LIM:ACP:ACH:ABS:STAT ON
Switches on the check of absolute limit values for the adjacent
channels.
INIT;*WAI
Starts a new measurement and waits for the sweep end.
CALC:LIM:ACP:ACH:RES?
Queries the limit check result in the adjacent channels.
CALCulate<n>:LIMit<k>:ACPower:ACHannel:ABSolute <LowerLimit>,
<UpperLimit>
This command defines the absolute limit value for the lower/upper adjacent channel
during adjacent-channel power measurement (Adjacent Channel Power).
Note that the absolute limit value has no effect on the limit check as soon as it is below
the relative limit value defined with CALCulate<n>:LIMit<k>:ACPower:
ACHannel[:RELative]. This mechanism allows automatic checking of the absolute
basic values of adjacent-channel power as defined in mobile radio standards.
Suffix:
<n>
.
Selects the measurement window.
<k> irrelevant
Parameters:
<LowerLimit>,
<UpperLimit>
first value: -200DBM to 200DBM; limit for the lower and the
upper adjacent channel
*RST: -200DBM
Example:
CALC:LIM:ACP:ACH:ABS -35DBM, -35DBM
Sets the absolute limit value for the power in the lower and
upper adjacent channel to -35 dBm.
CALCulate<n>:LIMit<k>:ACPower:ACHannel:ABSolute:STATe <State>
This command activates the limit check for the adjacent channel when adjacent-chan-
nel power measurement (Adjacent Channel Power) is performed. Before the com-
mand, the limit check for the channel/adjacent-channel measurement must be globally
switched on using CALCulate<n>:LIMit<k>:ACPower[:STATe].