Remote Control Commands
R&S
®
SMB100A
425Operating Manual 1407.0806.32 ─ 13
Use the SCPI command [:SOURce]:STEReo:PILot:STATe instead.
Setting parameters:
<State> 0 | 1
Example:
STEReo:DIRect "PIL=1"
The pilot tone is activated.
Example:
STEReo:DIRect? "PIL"
Response: "1"
STEReo:DIRect "PIL-DEV=<Deviation>"
STEReo:DIRect? "PIL-DEV"
(for documentation reasons only)
Sets the pilot tone frequency deviation (max. deviation).
Use the SCPI command [:SOURce]:STEReo:PILot[:DEViation] instead.
Setting parameters:
<Deviation> Note: A four-digit value must always be set. Leading zeros, if any,
must also be specified.
Range: 0000 to 1000 (ASCII coded decimal numbers), cor-
responding to 0 Hz to 10 kHz
Example:
STEReo:DIRect "PIL-DEV=1000"
Sets the frequency deviation of the pilot tone to 10 kHz.
Example:
STEReo:DIRect? "PIL-DEV"
Response: "1000"
STEReo:DIRect "PIL-PH=<Phase>"
STEReo:DIRect? "PIL-PH"
(for documentation reasons only)
Sets the pilot tone phase.
Use the SCPI command [:SOURce]:STEReo:PILot:PHASe instead.
Setting parameters:
<Phase> Note: A two-digit value must always be set with a sign ("+" or "-")
in front of it. Leading zeros, if any, must also be specified.
Range: -5.0 to +5.0 (ASCII coded decimal numbers), cor-
responding to ±5.0
Example:
STEReo:DIRect "PIL-PH=-33"
The pilot tone phase is set to 3.3
Example:
STEReo:DIRect? "PIL-PH"
Response: "-33"