Technical data
Table 7- 27 Technical specifications of MDS D261
6GT2600-1AA01-0AX0
Product type designation
SIMATIC MDS D261
Memory
Memory configuration
UID 8 bytes
User memory 256 bytes EEPROM
OTP memory 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
years
Mechanical specifications
Housing
Material Top PET plastic (label
material)
Inlay PET plastic (carrier
material)
Antenna Aluminum
Bottom Double-sided trans-
fer adhesive on sili-
con paper
Color White
Recommended distance to metal
> 25 mm
Power supply
Inductive, without battery