EasyManuals Logo

Siemens SIMATIC Ident System Manual

Siemens SIMATIC Ident
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #228 background imageLoading...
Page #228 background image
Transponder
7.11 MDS D261
SIMATIC RF200
228 System Manual, 07/2015, J31069-D0227-U001-A9-7618
Type of delivery
Minimum order quantity: 1250 units (5 rolls with 250 units each)
7.11.3
Technical data
Table 7- 27 Technical specifications of MDS D261
6GT2600-1AA01-0AX0
Product type designation
SIMATIC MDS D261
Memory
Memory configuration
• UID • 8 bytes
• User memory • 256 bytes EEPROM
• OTP memory • 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
years
Mechanical specifications
Housing
• Material • Top • PET plastic (label
material)
• Inlay • PET plastic (carrier
material)
• Antenna • Aluminum
• Bottom • Double-sided trans-
fer adhesive on sili-
con paper
• Color • White
Recommended distance to metal
> 25 mm
Power supply
Inductive, without battery

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals