Transponder
7.12 MDS D324
SIMATIC RF200
232 System Manual, 07/2015, J31069-D0227-U001-A9-7618
7.12.4
Technical specifications
Table 7- 30 Technical specifications of MDS D324
6GT2600-3AC00
Product type designation
SIMATIC MDS D324
Memory
Memory configuration
UID 8 bytes
User memory 992 bytes EEPROM
OPT memory 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
hours
Mechanical specifications
Housing
Material Epoxy resin
Color Black
Recommended distance to metal
> 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
During operation -25 to +125 ℃
During transportation and storage -40 to +140 ℃
Degree of protection to EN 60529
IP67
IPx9K
Shock-resistant to EN 60721-3-7 class 7M3
100 g
1)
Vibration-resistant to EN 60721-3-7, class 7M3
20 g
1)
Torsion and bending load Not permitted