Readers   
5.3 SIMATIC RF220R 
  SIMATIC RF200 
106  System Manual, 07/2015, J31069-D0227-U001-A9-7618 
 
Permitted ambient conditions 
•  During operation  •  -20 … +70 °C 
•  During transportation and storage  •  -25 … +85 °C 
Degree of protection to EN 60529 
Shock-resistant to EN 60721-3-7, Class 7 M3  
Vibration-resistant to EN 60721-3-7, Class 7 M3 
 
Design, dimensions and weights 
Cable length for RS-422 interface, maximum 
LED display design  3-color LED 
(operating voltage, presence, error) 
 
Approvals 
FCC information 
Siemens SIMATIC RF220R (MLFB 6GT2821-2AC10) FCC ID NXW-RF220R
 
This device complies with part 15 of the FCC rules. Operation is subject to the following two 
conditions:  
(1) This device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that may cause 
undesired operation. 
 
Any changes or modifications not expressly approved by the party responsible for 
compliance could void the user's authority to operate the equipment. 
 
This equipment has been tested and found to comply with the limits for a Class A digital 
device, pursuant to part 15 of the FCC Rules.  
These limits are designed to provide reasonable protection against harmful interference 
when the equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance 
with the instruction manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful interference in 
which case the user will be required to correct the interference at his own expense.