Transponder
7.22 MDS D460
SIMATIC RF200
272 System Manual, 07/2015, J31069-D0227-U001-A9-7618
7.21.5
Dimension drawing
Dimensions in mm
Figure 7-53 Dimension drawing of MDS D428
7.22
MDS D460
7.22.1
Characteristics
MDS D460
Characteristics
Area of application Identification in small assembly lines; can also be used in a harsh in-
dustrial environment
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 37).
Mounting on metal
Yes, with spacer
ISO standard
ISO 15693
Degree of protection
IP67/IPx9K