Transponder
7.26 MDS D524
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
291
7.26.4
Technical specifications
Table 7- 65 Technical specifications for MDS D524
6GT2600-5AC00
Product type designation
SIMATIC MDS D524
Memory
Memory configuration
• UID • 8 bytes
• User memory • 8192 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
hours
Mechanical specifications
Housing
• Material • Epoxy resin
• Color • Black
Recommended distance to metal
> 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• During operation • -25 to +85 ℃
• During transportation and storage • -40 to +100 ℃
Degree of protection to EN 60529
• IP67
• IPx9K
Shock-resistant to EN 60721-3-7 class 7M3
100 g
1)
Vibration-resistant to EN 60721-3-7, class 7M3
20 g
1)
Torsion and bending load
Not permitted

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals