EasyManua.ls Logo

Siemens SIMATIC Ident - Technical Specifications

Siemens SIMATIC Ident
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Transponder
7.8 MDS D160
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
217
7.8.4
Technical specifications
Table 7- 20 Technical specifications for the MDS D160
6GT2600-0AB10
Product type designation
SIMATIC MDS D160
Memory
Memory configuration
UID 8 bytes
User memory 112 bytes EEPROM
OPT memory 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
years
Mechanical specifications
Housing
Material
Color
PPS
beige
Recommended distance to metal
> 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
In operation, during write/read access -25 … +85 °C
In operation, outside write/read access -40 … +175 °C
from +125 ℃: for 1000 hours, 20% reduction
of the limit distance
from +140 ℃: No processing possible
at +175 ℃: 100 washing cycles tested
at +220 ℃: Tested once for up to 30 seconds
During transportation and storage -25 to +100 ℃