RF200 system planning
4.3 Installation guidelines
SIMATIC RF200
50 System Manual, 07/2015, J31069-D0227-U001-A9-7618
4.3.4
Impact of metal on the transmission window
In general, the following points should be considered when mounting RFID components:
Direct mounting on metal is allowed only in the case of specially approved transponders.
Flush-mounting of the components in metal reduces the field data; a test is recommended
in critical applications.
When working inside the transmission window, make sure that no metal rail (or similar
part) intersects the transmission field.
The metal rail would affect the field data.
With readers with a large antenna surface (e.g. RF260R) for reasons of communication
reliability, when the transponders are flush mounted in metal, a metal-free space around
the transponders is recommended. This metal-free space should match the size of the
antenna surface.
The impact of metal on the field data (S
g
, S
a
, L) is shown in a table in this section. The
values in the tables describe field data reduction and show the reduced range as a
percentage. The range relates to use in a non-metallic environment. A value of 100% means
no influence on the range.

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals