Transponder
7.25 MDS D522 special variant
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
287
7.25.5
Technical specifications
Table 7- 62 Technical data of MDS D522 special version
6GT2600-5AF00-0AX0
Product type designation
SIMATIC MDS D522 special version
Memory
Memory configuration
UID 8 bytes
User memory 8192 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
hours
Mechanical specifications
Housing
Material Plastic PA 6.6 GF
Color Black
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
During operation -25 to +85 ℃
During transportation and storage -40 to +100 ℃
Degree of protection to EN 60529 IP68
2 hours, 2 bar, +20 °C
Shock-resistant to EN 60721-3-7 class 7M3
50 g
1)
Vibration-resistant to EN 60721-3-7, class 7M3 20 g
1)
Torsion and bending load Not permitted
Design, dimensions and weight
Dimensions (Ø x H) 18 (+0.1) × 5.2 mm
Weight Approx. 1.2 g
Type of mounting
Clipping in once (with accompanying tool)
1)
The values for shock and vibration are maximum values and must not be applied continuously.