Transponder
7.9 MDS D165
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
221
7.9.3
Technical data
Table 7- 22 Technical specifications for MDS D165
6GT2600-1AB00-0AX0
Product type designation
SIMATIC MDS D165
Memory
Memory configuration
• UID • 8 bytes
• User memory • 112 bytes EEPROM
• OPT memory • 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
hours
Mechanical specifications
Housing
• Material • Top • PET plastic (label
material)
• Inlay • PET plastic (carrier
material)
• Antenna • Aluminum
• Bottom • Double-sided trans-
fer adhesive on sili-
con paper
• Color • White
Recommended distance to metal
> 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• During operation • -25 to +85 ℃
• During transportation and storage • +20 to +30 ℃
Can be stored for 2 years, determined by the
durability of the adhesive.
Degree of protection to EN 60529
IP65

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals