Transponder
7.22 MDS D460
SIMATIC RF200
274 System Manual, 07/2015, J31069-D0227-U001-A9-7618
7.22.4
Technical specifications
Table 7- 56 Technical specifications for MDS D460
6GT2600-4AB00
Product type designation
SIMATIC MDS D460
Memory
Memory configuration
• UID • 8 bytes
• User memory • 2000 bytes FRAM
• OPT memory • 16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
hours
Mechanical specifications
Housing
• Material • Epoxy resin
• Color • Black
Recommended distance to metal
> 10 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• During operation • -25 to +85 ℃
• During transportation and storage • -40 to +100 ℃
Degree of protection to EN 60529
• IP67
• IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock-resistant to IEC 68-2-27
50 g
1)
Vibration-resistant to IEC 68-2-6
20 g
1)
Torsion and bending load Not permitted

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals