Transponder
7.7 MDS D139
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
211
7.7.6
Technical specifications
Table 7- 17 Technical specifications for MDS D139
6GT2600-0AA10
Product type designation
SIMATIC MDS D139
Memory
Memory configuration
UID 8 bytes
User memory 112 bytes EEPROM
OPT memory 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
years
Mechanical specifications
Housing
Material PPS
Color Black
Recommended distance to metal
> 30 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
During operation -25 to +220 ℃
from +125 ℃: 20% reduction in the limit dis-
tance
from +140 ℃: No processing possible
at +200 ℃: Tested up to 5000 hours or
6000 cycles
at +220 ℃: Tested up to 2000 hours or
2000 cycles
During transportation and storage -40 to +100 ℃

Table of Contents