EasyManuals Logo

Siemens SIMATIC Ident System Manual

Siemens SIMATIC Ident
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #251 background imageLoading...
Page #251 background image
Transponder
7.16 MDS D422
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
251
7.16
MDS D422
7.16.1
Characteristics
MDS D422
Characteristics
Area of application
Identification of metallic workpiece holders, workpieces or
containers
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 37).
Mounting on metal Yes
ISO standard
ISO 15693
Degree of protection
IP68
7.16.2
Ordering data
Table 7- 39 Ordering data of MDS D422
Article number
MDS D422
A screw-in aid is included in the scope of supply per packaging
unit
6GT2600-4AF00
7.16.3
Mounting in metal
Flush-mounting
Figure 7-40 Mounting of MDS D422 in metal

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals