Transponder
7.16 MDS D422
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
251
7.16
MDS D422
7.16.1
Characteristics
MDS D422
Characteristics
Area of application
Identification of metallic workpiece holders, workpieces or
containers
Memory size
2000 bytes of FRAM user memory
Write/read range
See section "Field data (Page 37).
Mounting on metal Yes
ISO standard
ISO 15693
Degree of protection
IP68
7.16.2
Ordering data
Table 7- 39 Ordering data of MDS D422
Article number
MDS D422
A screw-in aid is included in the scope of supply per packaging
unit
6GT2600-4AF00
7.16.3
Mounting in metal
Flush-mounting
Figure 7-40 Mounting of MDS D422 in metal