Transponder
7.24 MDS D522
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
281
7.24
MDS D522
7.24.1
Characteristics
MDS D522
Characteristics
Area of application Identification of metallic workpiece holders, work-
pieces or containers
Memory size
8192 bytes of FRAM user memory
Write/read range
See "Field data (Page 37)."
Mounting in metal Yes
ISO standard
ISO 15693
Degree of protection
IP68
7.24.2
Ordering data
Table 7- 59 Ordering data for MDS D522
Article number
MDS D522
Units in a package: 10 units
A mounting aid is included in the scope of supply per packaging
unit.
6GT2600-5AF00
7.24.3
Mounting in metal
Flush-mounting
Figure 7-63 Mounting of MDS D522 in metal