Appendix
A.2 Accessories
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
317
A.2.2.7
Parameterization
Parameter settings can be performed using the tool "RF290R-Set" (V9.5.2).
This tool is primarily used for parameterization and commissioning, and is not designed for
productive operation.
The relevant parameters of the RF260X can be set in the "Configuration" menu under
"SystemParameters > CFG15: Antenna Multiplexing"
Figure A-3 Menu "Configuration" MOBYDSet"
For operation with RF260X, you need to activate the "Multiplexing" function .
The number of occupied channels must be specified under "Number of Output Channels"
.
In "Multiplexer Valid Times"
, the maximum time available for the antenna to read a
transponder is entered. Following this time, the device switches to the next antenna
automatically. If the read was successful, the time may be significantly shorter than
specified here.