EasyManuals Logo

Siemens SIMATIC Ident System Manual

Siemens SIMATIC Ident
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #198 background imageLoading...
Page #198 background image
Transponder
7.4 MDS D124
SIMATIC RF200
198 System Manual, 07/2015, J31069-D0227-U001-A9-7618
7.4.4
Technical specifications
Table 7- 8 Technical specifications for MDS D124
6GT2600-0AC10
Product type designation
SIMATIC MDS D124
Memory
Memory configuration
• UID • 8 bytes
• User memory • 112 bytes EEPROM
• OPT memory • 20 bytes EEPROM
Read cycles (at < 40 ℃)
> 10
14
Write cycles (at < 40 ℃)
> 10
6
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
years
Mechanical specifications
Housing
• Material • PPS
• Color • Black
Recommended distance to metal
> 15 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• During operation • -25 to +180 ℃
• from +125 ℃: 20% reduction in the limit dis-
tance
• from +140 ℃: No processing possible
• at +180 ℃: Tested up to 5000 hours or
3000 cycles
• During transportation and storage • -40 to +125 ℃
Degree of protection to EN 60529
• IP68
2 hours, 2 bar, +20 °C
• IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock-resistant to EN 60721-3-7 class 7M3
100 g
1)

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals