Appendix
A.2 Accessories
SIMATIC RF200
318 System Manual, 07/2015, J31069-D0227-U001-A9-7618
Note
Changing the parameter assignment
Note that if you change the parameter settings of the reader or the RF260X in scanner
mode, this may lead to frame collisions. These collisions result when the frame is sent
while a transponder is present.
The "Transponder response time" (setting: "CFG2: COM interface") during operation of
the RF260X must be higher than the total delay time for all the connected antennas
(CFG15: MUX-VALD-TIME × Number of Output Channels ≤ Transponder Response
Time)
A.2.2.8
RF260X commands
Using the tool "RF290R-Set" (V9.5.2), certain commands can also be sent to the RF260X. In
the "Commands" menu under "RF260X", the following commands can be sent:
Detect (detection of the RF260X by the reader)
Channel Select (set to a static channel)
CPU-Reset (restart the RF260X software)
Software Version (read out software and hardware versions)
Figure A-4 Sending commands from the "RF290R-Set" tool