Transponder
7.28 MDS D528
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
297
7.28.3
Application example
Figure 7-72 Application example
7.28.4
Technical specifications
Table 7- 70 Technical specifications for MDS D528
6GT2600-5AK00
Product type designation SIMATIC MDS D528
Memory
Memory configuration
UID 8 bytes
User memory 8192 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
hours