EasyManuals Logo

Siemens SIMATIC Ident System Manual

Siemens SIMATIC Ident
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
RF200 system planning
4.2 Field data of transponders and readers
SIMATIC RF200
44 System Manual, 07/2015, J31069-D0227-U001-A9-7618
4.2.2
Minimum clearances
Minimum distance from transponder to transponder
The specified distances refer to a metal-free environment. For a metallic environment, the
specified minimum distances must be multiplied by a factor of 1.5.
Table 4- 13 Minimum clearances for transponders
RF210R
RF220R
RF240R
RF260R
MDS D100
--
--
--
≥ 240
MDS D117
≥ 15 -- -- --
MDS D124
≥ 25
≥ 40
≥ 90
≥ 180
MDS D126
-- ≥ 50 ≥ 100 ≥ 180
MDS D127
≥ 15
--
--
--
MDS D139
--
--
--
≥ 200
MDS D160
≥ 20
≥ 25
≥ 70
≥ 150
MDS D165
--
--
--
≥ 240
MDS D200
--
--
--
≥ 240
MDS D261
--
--
--
≥ 200
MDS D324
≥ 25
≥ 40
≥ 90
≥ 180
MDS D339
--
--
--
≥ 200
MDS D400
--
--
--
≥ 240
MDS D421
≥ 10
--
--
--
MDS D422
≥ 15
≥ 20
≥ 50
--
MDS D423
--
--
≥ 80
≥ 160
MDS D424
≥ 25
≥ 40
≥ 90
≥ 180
MDS D425
≥ 20
≥ 25
≥ 75
--
MDS D426
--
≥ 50
≥ 90
≥ 180
MDS D428
≥ 25
≥ 25
≥ 75
≥ 150
MDS D460
≥ 20 ≥ 25 ≥ 70 ≥ 150
MDS D521
≥ 10
--
--
--
MDS D522
≥ 15
≥ 20
≥ 50
--
MDS D522
Special variants
≥ 15 ≥ 20 ≥ 50 --
MDS D524
≥ 25 ≥ 40 ≥ 90 ≥ 180
MDS D526
--
≥ 50
≥ 90
≥ 180
MDS D528
≥ 25
≥ 25
≥ 75
≥ 150
All values are in mm, relative to the operating distance (S
a
) between reader and transponder, and
between transponder edge and transponder edge

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals