Transponder
7.17 MDS D423
SIMATIC RF200
256 System Manual, 07/2015, J31069-D0227-U001-A9-7618
Figure 7-44 Flush-mounting of the MDS D423 in metal without clearance
Note
Reduction of the write/read range
Note that when the device is
flush-mounted in metal without a surrounding clearance ≥ 10
mm, the write/read range is significantly reduced.
7.17.4
Technical specifications
Table 7- 43 Technical specifications of MDS D423
6GT2600-4AA00
Product type designation
SIMATIC MDS D423
Memory
Memory configuration
• UID • 8 bytes
• User memory • 2000 bytes FRAM
• OPT memory • 16 bytes FRAM
Read cycles (at < 40 ℃)
> 10
12
Write cycles (at < 40 ℃)
> 10
12
Data retention time (at < 40 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
6
hours