7.17 MDS D423
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
257
6GT2600-4AA00
Mechanical specifications
Housing
• Material • Plastic PPS
• Color • Black
Recommended distance to metal
> 0 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
• During operation • -25 to +85 ℃
• During transportation and storage • -40 to +100 ℃
Degree of protection to EN 60529
• IP68
2 hours, 2 bar, +20 °C
• IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
Shock-resistant to EN 60721-3-7 class 7M3
50 g
1)
Vibration-resistant to EN 60721-3-7, class 7M3
20 g
1)
Pressure resistance
• Low pressure resistant
vacuum dryer: up to 20 mbar
• High pressure resistant
(see degree of protection IPx9K)
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (Ø x H)
30 x 8 mm
Weight
15 g
Type of mounting 1 x M4 screw
2)
≤ 1 Nm
1)
The values for shock and vibration are maximum values and must not be applied continuously.
2
) To prevent it loosening during operation, secure the screw with screw locking varnish.

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals