Transponder
7.8 MDS D160
SIMATIC RF200
216 System Manual, 07/2015, J31069-D0227-U001-A9-7618
7.8.3
Mounting on metal
Mounting on metal
h
≥ 10 mm
Figure 7-16 Mounting the MDS D160 on metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results.
In critical applications, it is recommended that a test is performed.
Flush-mounting
Flush-mounting of the MDS D160 in metal is not permitted!