Applications Guide
Network Busy Lamp Field (BLF)
A-16 Strata CIX Programming Vol.1 12/09
Programming Network BLF from Network eManager for Digital Telephones
Perform all of the following steps on the local CIX first, then repeat them on each of the remote CIXs.
1. Create the Node ID in “102 Flexible Access Codes” on page 4-3.
Note If you have already created the Node ID using Strata Net, skip Step 1 and go to the next step.
2. Set up the IP address of the primary CIX using Program “916 IP Configuration” on page 10-10.
3. In Network eManager, select Strata Net > Node ID to set the Primary Node ID. Refer to “656 Node ID
Assignment” on page 9-33.
4. In Network eManager, select System > I/O Device. Refer to Program “803 Application Port
Assignments” on page 4-36.
00 Logical Device No. = 400 (BLF)
01 Device Connection = LAN
02 Device Port No. = 11
5. Define the LAN Device port number (11 in the example above). Select System > I/O Device, select the
LAN Device tab. Refer to “801 Network Jack LAN Device Assignmenton page 4-39. Make the
following selections:
00 LAN Port No. = 11
01 Protocol = TCP
02 Application Type = Server
03 Data Flow = Asynchronization
04 Server Port No. = 6000
05 Client IP 1-4 No. = Default
06 Client Port No. = Default
07 Read Retry No. = 1
08 Write Retry No. = 1
09 CallerName Set to CSTA = No
6. Verify the DSS refresh time in System > System Timer, field 23 – Network DSS Refresh Timer. Refer to
“104 System Timer” on page 4-12.
7. From each remote CIX, repeat steps 1~6 to set up Network BLF.