EasyManua.ls Logo

Xerox PHASER 6250 - Replace Imaging Unit or Imaging Unit Is Near End of Life

Xerox PHASER 6250
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error Messages and Codes 3-43
Replace Imaging Unit or
Imaging Unit is Near End of Life
Print the Supplies Usage page and verify life remaining and date Imaging
Unit was installed.
Cycle printer power.
If the problem persists, follow the procedure below
Note
The “Imaging Unit is Near End of Life” is a warning. “Replace Imaging Unit” is
a hard stop.
Troubleshooting Reference Table
Applicable Parts Wiring and Plug/Jack Map References
Imaging Unit PL 9.1.3 “Laser Unit” on page 10-22
Troubleshooting Procedure Table
Steps Actions and Questions Yes No
1
Check the following parts for evidence of
fault or damage:
Imaging Unit PL 9.1.3
CRUM Connector on the Plate Dispenser
Replace the parts
concerned.
Go to Step 2.
2
Replace the Imaging Unit .
Does the error recur?
Go to Step 3. Complete
3
Verify the CRUM Harness is properly
connected.
See “Laser Unit” on page 10-22.
Go to Step 4. Replace the
CRUM Harness
Assembly,
PL 10.1.15.
4
Check CRUM Harness Assembly for
continuity.
See “Laser Unit” on page 10-22.
Go to Step. 5. Replace the
CRUM Harness
Assembly,
PL 10.1.15.
5
Check the EEPROM Harness for
continuity.
See “Fuser Assembly” on page 10-21.
Replace the
Engine Control
Board,
page 8-107.
Replace EEPROM
Harness
Assembly,
PL 13.1.10.

Table of Contents