Service Parts Disassembly 8-47
Chute Assembly Out
Chute Assembly Out (PL6.1.1)
1. Remove the Imaging Unit (Routine Maintenance Item) (page 8-4) and protect it
from exposure to light.
2. Remove the Transfer Roller (Routine Maintenance Item) (page 8-4).
3. Remove the Fuser Assembly (Routine Maintenance Item) (page 8-5).
4. Remove all Covers and Tray 1 (page 8-6, page 8-9, page 8-11, page 8-12,
page 8-14, page 8-15, and page 8-16).
Caution
Support the Chute Assembly Out (Door B) while removing the strap to
prevent damage to the printer.
5. Remove the strap (page 8-67).
6. Close the Chute Assembly Out (Door B) and the Chute Assembly In (Door A)
while disconnecting wiring harnesses to avoid damaging the printer.
7. Disconnect all connectors going to the front of the left side connector block.
8. Disconnect the lower (grey) connector (P/J145) from the EEPROM board.
9. Disconnect the two red wired spade lug connectors (P/J5020 and P/J5030) from
the Sub-HVPS board.
10. Remove 1 screw securing the ground wire to the left side of the printer.
11. Free the harness from the wire guides at the bottom of the Housing Assembly.

Table of Contents

Other manuals for Xerox PHASER 6250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xerox PHASER 6250 and is the answer not in the manual?

Xerox PHASER 6250 Specifications

General IconGeneral
BrandXerox
ModelPHASER 6250
CategoryPrinter
LanguageEnglish

Related product manuals