6.5 One-parameter Tuning (Fn203)
6-37
6
Adjustments
(2) Digital Operator Operating Procedure
Setting the Tuning Mode 0 or 1
Step Display after Operation Keys Operation
1
Press the Key to view the main menu for the
utility function.
Press the or Key to move through the list
and select Fn203.
2
Press the Key to display the mass ratio set in
Pn103 at present. Move the digit with the or
Key and change the value with the or
Key.
3
Press the Key to display the initial setting screen
for one-parameter tuning.
4
Press the , , or Key and set the items in
steps 4-1 and 4-2.
4-1
Tuning Mode
Select the tuning mode
. Select the tuning mode 0 or 1.
Tuning Mode = 0: Makes adjustments giving priority to stability.
Tuning Mode = 1: Makes adjustments giving priority to respon
siveness.
4-2
Type Selection
Select the type according to the machine element to be driven.
If there is noise or the gain does not inc
rease, better results may be obtained by changing the rigidity type.
Type = 1: Low rigidity
Type = 2: Medium rigidity [Factory setting]
Type = 3: High rigidity
5
If the servomotor power is OFF, input a servo ON
sign
al (/S-ON) from the host controller. The display
will change from "BB" to "RUN."
If the servomotor power is ON, go to step 6.
6
Press the Key to display the set value.
7
Press the Key again to display the LEVEL set-
ting screen.
Note: The status display will always be RUN
when the servomotor power is ON.
㧮㧮ޓ ޓ㧲㨁㧺㧯㨀㧵㧻
㧲㨚㧞㧜㧞㧦㧾㨑㨒㧭㧭㨀
㧲㨚㧞㧜㧟㧦㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧲㨚㧞㧜㧠㧦㧭㨂㨕㨎ޓ㧿㨡㨜
㧲㨚㧞㧜㧡㧦㨂㨕㨎ޓ㧿㨡㨜
㨚
Status Display
㨚
㧿
㨚
㧿
㧾㨁㧺 㨚
㧿㨑㨠㨠㨕㨚
㧾㨁㧺㧻㨚㨑㧼㨞㨙㨀㨡
㧼㨚㧝㧜㧜㧩㧜㧜㧠㧜㧜
㧼㨚㧝㧜㧝㧩㧜㧜㧞㧜㧜㧜
㧼㨚㧝㧜㧞㧩㧜㧜㧠㧜㧜
㧾㨁㧺㧻㨚㨑㧼㨞㨙㨀㨡㨚
㧸㧱㨂㧱㧸㧩㧜㧜㧡
ޓ㧺㧲㧝ޓ㧺㧲㧞
㧭㧾㧱㧿