GPIB Operation ML24xxA Native Commands
ML2437A/38A OM/PM PN: 10585-00001 Rev. P 8-71
SRCSPPWR (Source Sweep Stop Power)
SRCSTAT (Source Sweep mode status request)
SRCSTFRQ (Source Sweep Start Frequency)
SRCSTPWR (Source Sweep Start Power)
Syntax: SRCSPPWR <power_value>
power value: power
Remarks: Determines the stop power level of power sweep mode.
Query: SRCSPPWR?
Returned String: SRCSPPWR <power>
Syntax: SRCSTAT
Remarks: Requests the source sweep status, and returns the following message:
SRCSWP<ws><mode>,<start_power>,<stop_power>,<start_freq>,<stop
_freq>
Syntax: SRCSTFRQ <freq_value>[units]
freq value: 10 kHz to 122 GHz
Remarks: Determines the start frequency when in frequency sweep mode.
Query: SRCSTFRQ?
Returned String: SRCSTFRQ <frequency>
Syntax: SRCSTPWR <power_value>
power value: power
Remarks: Determines the start power level of power sweep mode.
Query: SRCSTPWR?
Returned String: SRCSTPWR <power>