5. Troubleshooting
19
Image 5-19
Code 7605: “Red DMD temp short” (Error)
Situation Solution
Damaged wire unit of the
temperature sensor (reference
19 image 5-19 and image 5-18)
which m easures the temperature of
the DM D of the RED channel.
Repair or replace the wire unit.
Defect temperature sensor
(reference 19 image 5-19) which
measures the temperature of the
DMD of the RED channel.
Replace the temperature sensor on the cooling block of the RED channel.
Code 7606: “Green DMD temp low” (Error)
This error code is probably preceded by the warning code 7607: “Green DMD tem p low”. The sa me troubleshooting table can be
applied to.
Code 7607: “Green DMD temp low” (Warning)
Situation Solution
The elec tronics of the L ight
Processor Unit remains off due to a
low DMD temperature.
Make sure that the ambient tem perature is within specs: higher then 10°C (50°F). Let
the projector acclim ate. Do not ignite the lamp, otherwise there is a risk for condensate.
Defect temperature sensor
(reference 18 image 5-20) which
measures the temperature of the
DMD of the GREEN channel.
Replace the temperature s ensor on the cooling block of the GREEN channel.
18
Image 5-20
56 R5905312 HDF W SERIES 24/01/2013