Chapter 7: Maintenance
System Alarm Tables
7-18 011-003-991 EN
USB Memory Full USB Memory Full Data was selected to be
saved on the USB memory
stick, but the memory stick
is now full.
Welding will be stopped until
corrected. If all data from the weld will
not fit, then no data will be written. All
data from any given weld cycle must
be written on one USB stick.
USB Memory Lost USB Memory Failure The USB memory stick has
been removed or it is not
functional.
Since weld data was configured to be
saved on the USB stick, welding must
be stopped until either the USB stick is
functional or weld data is no longer
required to be saved.
2000a
2000dt
2000e
2000t
Wrong Actuator Wrong Actuator ae/
aed cannot be used
with this level control
The Power Supply has
detected an Actuator that
cannot be used with a
Power Supply of this type.
Use the correct Actuator for this
Power Supply.
Table 7.5 Failure of Alarms and Messages, with Probable Cause
and Corrective Action (Continued)
Model
Display
Message
Printer Message
Alarm Condition/
Cause
Corrective Action