Chapter 7: Maintenance
System Alarm Tables
7-28 011-003-991 EN
2000a
2000dt
2000e
Cutoff Conflict The plus reject power limit is equal to or greater
than the peak power cutoff value.
Change the +reject power limit or peak
power cutoff through the Alarm
Information screen or Setup menu.
2000a
2000dt
2000e
Cutoff Conflict The minus suspect power limit is equal to or
greater than the peak power cutoff value.
Change the - suspect power limit or peak
power cutoff through the Alarm
Information screen or Setup menu.
2000a
2000dt
2000e
Cutoff Conflict The plus suspect power limit is equal to or less
than the peak power cutoff value.
Change the +suspect power limit or peak
power cutoff through the Alarm
Information screen or Setup menu.
2000a
2000dt
2000e
Energy Comp
Conflict
The plus reject energy limit is equal to or less than
the minimum energy compensation value. This
alarm occurs in time mode only.
Change the +Reject energy limit or
minimum energy compensation through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
Energy Comp
Conflict
The plus suspect energy limit is equal to or less
than the
minimum energy
compensation value. This alarm occurs in time
mode only.
Change the +Suspect energy limit or
minimum energy compensation through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
Energy Comp
Conflict
The minus reject energy limit is equal to or less
than the
maximum energy
compensation value. This alarm occurs in time
mode only.
Change the - Reject energy limit or
maximum energy compensation through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
Energy Comp
Conflict
The minus suspect energy limit is equal to or less
than the
maximum energy
compensation value. This alarm occurs in time
mode only.
Change the - Suspect energy limit or
maximum energy compensation through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
Energy Comp
Conflict
The minus reject energy limit is equal to or less
than the minimum energy compensation value.
Change the - Reject energy limit or
minimum energy compensation through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
Energy Comp
Conflict
The minus suspect energy limit is equal to or less
than the minimum energy compensation value.
Change the - Suspect energy limit or
energy compensation through the Alarm
Information screen or Setup menu.
Table 7.8 Setup Alarms and Messages, with Probable Cause
and Corrective Action (Continued)
Model
Display
Message
Alarm Condition/Cause Corrective Action