2000X energy Power Supply Chapter 7: Maintenance
Instruction Manual System Alarm Tables
011-003-991 EN 7-29
2000a
2000dt
2000e
Energy Comp
Conflict
The plus energy reject limit is equal to or greater
than the energy compensation
maximum value
Change the +Reject energy limit or
maximum energy compensation through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
Energy Comp
Conflict
The plus suspect energy limit is equal to or greater
than the energy compensation maximum value.
Change the +Suspect energy limit or
maximum energy compensation through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
Energy Comp
Crossed
The energy minimum and maximum settings are
crossed. This alarm is only valid when energy
compensation is on.
Change the minimum and maximum
energy compensation limits through the
Alarm Information screen or Setup menu.
2000a
2000dt
2000e
+- Eng Limit
Crossed
The suspect limits for energy that you have
entered are reversed.
Change the suspect energy limits
through the Alarm Information screen or
Setup menu.
2000a
2000dt
2000e
+- Eng Limit
Crossed
The reject limits for energy that you have entered
are reversed.
Change the reject energy limits through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
Eng S/R Limit
Cross
The plus reject energy limit is equal to or less than
the minus suspect energy limit.
Change the +reject energy limit or -
suspect energy limit through the Alarm
Information screen or Setup menu.
2000a
2000dt
2000e
Eng S/R Limit
Cross
The plus suspect energy limit is equal to or less
than the minus reject energy limit.
Change the +suspect energy limit or -
reject energy limit through the Alarm
Information screen or Setup menu.
2000a
2000dt
2000e
Eng S/R Limit
Cross
The plus reject energy limit is equal to or less than
the plus suspect energy limit.
Change the +reject energy limit or
+suspect energy limit through the Alarm
Information screen or Setup menu.
2000a
2000dt
2000e
Eng S/R Limit
Cross
The minus reject energy limit is equal to or greater
than the minus suspect energy limit.
Change the - reject energy limit or -
suspect energy limit through the Alarm
Information screen or Setup menu.
Force A > Pressure A force value was selected while the set pressure
was 80 psi, then the set pressure was reduced to
60 psi.
A new force value must be entered.
Table 7.8 Setup Alarms and Messages, with Probable Cause
and Corrective Action (Continued)
Model
Display
Message
Alarm Condition/Cause Corrective Action