OMA turnstile specific workaround, and click OK). Set Max waiting time before autolocking an
unlocked turnstile option according to the turnstile control unit settings (usually 15 seconds).
Table 47
. Settings of CONF1 dip-unit toggles for operating with GlasStile turnstiles
Because o non-shut-off passage timer and a non-standard control
panel design), there are certain restrictions on its operation as part of ACS:
● The control panel connection is performed only to the turnstile control unit directly. All
the passages authorized from the control panel will be recorded in the ACS as the break-
ins.
● No constant turnstile unlock mode from the ACS client.
● Some issues are likely to arise, when a passage by a card and pressing control panel
buttons occur simultaneously.
Pic 75
. Connecting GlasStile turnstile