8. Connecting doors
In this configuration, the controller can control one or two doors equipped with electromagnetic or
electromechanical locks or latches.
8.1 Connecting two doors. Overview
You can connect one or two doors to the controller. Below is the list of the equipment to be
connected to a door:
● Lock
● Door opening sensor (reed switch)
● IN reader
● OUT reader
● IN-request button
● OUT-request button
● Door blocking button
● Button for opening the door from security post
Pic 19. Example of hardware kit connection in Two Door configuration
On both Entrance and Exit sides, either a reader or an RTE button can be mounted. Separate
IN/OUT-readers, as well as RTE buttons, allow the system to correctly determine the direction of
passage through the door.
Door opening button for security post allows the guard to open the door. In this case, the event is
properly recorded by the system as a passage in an unknown direction sanctioned by the security
post.
1=ON, 2=OFF (selects Doors configuration).
Selects normal state of the first door opening sensor. *