xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
180
12-3 config bpdu_protection
Description
This command is used to configure the BPDU protection trap state or log state.
Format
config bpdu_protection [trap | log] [none | attack_detected | attack_cleared | both]
Parameters
trap - Specify the trap state.
log - Specify the log state.
none - Specify neither attack_detected nor attack_cleared is trapped or logged.
attack_detected - Specify events will be logged or trapped when the BPDU attacks is detected.
attack_cleared - Specify events will be logged or trapped when the BPDU attacks is cleared.
both - Specify the events of attack_detected and attack_cleared shall be trapped or logged.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To configure the BPDU protection trap state as both for the entire switch:
DGS-3420-28SC:admin#config bpdu_protection trap both
Command: config bpdu_protection trap both
Success.
DGS-3420-28SC:admin#
12-4 enable bpdu_protection
Description
This command is used to enable BPDU protection globally for the entire switch.
Format
enable bpdu_protection
Parameters