xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
17
Format
show environment
Parameters
None.
Restrictions
None.
Example
To display the switch hardware status:
DGS-3420-28SC:admin#show environment
Command: show environment
Internal Power : Active
External Power : Fail
Right Fan 1 : Speed Low (3000 RPM)
Right Fan 2 : Speed Low (3000 RPM)
Current Temperature(Celsius) : 30
Fan High Temperature Threshold(Celsius) : 40
Fan Low Temperature Threshold(Celsius) : 35
High Warning Temperature Threshold(Celsius) : 79
Low Warning Temperature Threshold(Celsius) : 11
DGS-3420-28SC:admin#
2-10 config temperature
Description
This command is used to configure the warning trap or log state of the system internal temperature.
Format
config temperature [trap | log] state [enable | disable]
Parameters
trap - Specify to configure the warning temperature trap.
log - Specify to configure the warning temperature log.
state - Enable or disable either the trap or log state for a warning temperature event. The default is
enable.