EasyManua.ls Logo

D-Link xStack DGS-3420 Series - Page 187

D-Link xStack DGS-3420 Series
1117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
182
12-6 show bpdu_protection
Description
This command is used to display BPDU protection global configuration or per port configuration and
current status.
Format
show bpdu_protection {ports {<portlist>}}
Parameters
ports - (Optional) Specify all ports to be displayed.
<portlist> - (Optional) Specify a range of ports to be displayed.
Restrictions
None.
Example
To display BPDU protection information for the entire switch:
DGS-3420-28SC:admin#show bpdu_protection
Command: show bpdu_protection
BPDU Protection Global Settings
---------------------------------------
BPDU Protection Status : Disabled
BPDU Protection Recover Time : 60 seconds
BPDU Protection Trap State : None
BPDU Protection Log State : Both
DGS-3420-28SC:admin#
To display BPDU protection status for ports 1 to 3:
DGS-3420-28SC:admin#show bpdu_protection ports 1-3
Command: show bpdu_protection ports 1-3
Port State Mode Status
----- ----------- ---------- -----------
1 Disabled Shutdown Normal
2 Disabled Shutdown Normal
3 Disabled Shutdown Normal
DGS-3420-28SC:admin#