xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
857
<ipv6addr> - Specifies the IPv6 used.
collectorport - (Optional) Specify the destination port for sending sflow datagrams.
<udp_port_number 1-65535> - Specify the destination port for sending sflow datagrams. The
number is between 1 and 65535.
maxdatagramsize - (Optional) Specify the maximum number of data bytes that can be packed in a
single sample datagram.
<value 300-1400> - Specify the maximum number of data bytes that can be packed in a single
sample datagram. The values is between 300 and 1400.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the sFlow analyzer server information:
DGS-3420-28SC:admin#config sflow analyzer_server 1 collectoraddress 10.90.90.9
Command: config sflow analyzer_server 1 collectoraddress 10.90.90.9
Success.
DGS-3420-28SC:admin#
12-10 show sflow analyzer_server
Description
This command is used to display sFlow analyzer server information.
Format
show sflow analyzer_server
Parameters
None.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To display sFlow analyzer server information: