DVP-15MC Series Motion Controller Operation Manual 
11-134 
Parameter name  Function  Data type  Valid range 
Error 
TRUE when there is an error in the execution of the 
instruction. 
BOOL  TRUE / FALSE 
ErrorID 
Contains error codes when an error occurs. Please 
refer to section 12.2 for the corresponding error code. 
WORD   
Touched  TRUE when one capture is finished by the instruction.
   
RecordedPosition 
The captured position after the completion of the 
instruction execution. 
LREAL   
  Output Update Timing 
Name  Timing for changing to TRUE  Timing for changing to FALSE 
Valid 
 When the instruction execution is normal 
as Enable is TRUE. 
 When Execute changes from TRUE to 
FALSE 
Busy 
 When Enable changes to TRUE. 
 When Done changes to TRUE. 
 When Error changes to TRUE. 
 When  CommandAborted 
Active 
 When Enable changes to TRUE. 
 When Done changes to TRUE. 
 When Error changes to TRUE. 
 When  CommandAborted 
CommandA
borted 
 When the instruction execution 
by some other motion control instruction. 
 When  Execute  changes  from  TRUE  to 
FALSE 
 CommandAborted is set to TRUE when the 
instruction execution is aborted after 
Execute 
changes from TRUE to FALSE 
during the instruction execution. One 
period later, CommandAborted 
Error 
 When an error occurs in the instruction 
execution or the input parameters for the 
instruction are illegal. 
 When  Execute  changes  from  TRUE 
FALSE   
  Output Update Timing Chart 
 
Enable
Valid
Busy
Active
CommandAborted
Error
Error ID
Case1 Case2
Touched
 
Case 1:  When Enable changes from FALSE to TRUE, Valid and Busy change to TRUE. One period later, 
Active changes to TRUE. When one capture is completed, Touched changes to TRUE and the 
TRUE state will last for one period. When Enable changes from TRUE to FALSE, Valid, Busy and 
Active change to FALSE. 
 
Case 2:  When an error exists in input parameters and Enable changes from FALSE to TRUE, Busy and