EasyManuals Logo

Edge-Core ECS2100-28T Reference Guide

Edge-Core ECS2100-28T
725 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
Chapter 5
| SNMP Commands
SNMP Target Host Commands
– 166
version
- Specifies whether to send notifications as SNMP Version 1, 2c or 3
traps. (Range: 1, 2c, 3; Default: 1)
auth
|
noauth
|
priv
- This group uses SNMPv3 with authentication, no
authentication, or with authentication and privacy. See “Simple
Network Management Protocol” in the Web Management Guide for
further information about these authentication and encryption
options.
port - Host UDP port to use. (Range: 1-65535; Default: 162)
Default Setting
Host Address: None
Notification Type: Traps
SNMP Version: 1
UDP Port: 162
Command Mode
Global Configuration
Command Usage
If you do not enter an
snmp-server host
command, no notifications are sent. In
order to configure the switch to send SNMP notifications, you must enter at
least one
snmp-server host
command. In order to enable multiple hosts, you
must issue a separate
snmp-server host
command for each host.
The
snmp-server host
command is used in conjunction with the snmp-server
enable traps command. Use the snmp-server enable traps command to enable
the sending of traps or informs and to specify which SNMP notifications are
sent globally. For a host to receive notifications, at least one snmp-server
enable traps command and the
snmp-server host
command for that host
must be enabled.
Some notification types cannot be controlled with the snmp-server
enable traps command. For example, some notification types are always
enabled.
Notifications are issued by the switch as trap messages by default. The recipient
of a trap message does not send a response to the switch. Traps are therefore
not as reliable as inform messages, which include a request for
acknowledgement of receipt. Informs can be used to ensure that critical
information is received by the host. However, note that informs consume more
system resources because they must be kept in memory until a response is
received. Informs also add to network traffic. You should consider these effects
when deciding whether to issue notifications as traps or informs.
To send an inform to a SNMPv2c host, complete these steps:
1.
Enable the SNMP agent (page 161).
2.
Create a view with the required notification messages (page 173).
3.
Create a group that includes the required notify view (page 170).

Table of Contents

Other manuals for Edge-Core ECS2100-28T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS2100-28T and is the answer not in the manual?

Edge-Core ECS2100-28T Specifications

General IconGeneral
BrandEdge-Core
ModelECS2100-28T
CategorySwitch
LanguageEnglish

Related product manuals