Chapter 4
| System Management Commands
File Management
– 110
Any changes made to the default setting can be displayed with the show
running-config or show startup-config commands.
Example
Console(config)#upgrade opcode auto
Console(config)#upgrade opcode path tftp://192.168.0.1/sm24/
Console(config)#
If a new image is found at the specified location, the following type of messages
will be displayed during bootup.
.
.
.
Automatic Upgrade is looking for a new image
New image detected: current version 1.1.1.0; new version 1.1.1.2
Image upgrade in progress
The switch will restart after upgrade succeeds
Downloading new image
Flash programming started
Flash programming completed
The switch will now restart
.
.
.
upgrade opcode path
This command specifies an TFTP server and directory in which the new opcode is
stored. Use the
no
form of this command to clear the current setting.
Syntax
upgrade opcode path
opcode-dir-url
no
upgrade opcode path
opcode-dir-url - The location of the new code.
Default Setting
None
Command Mode
Global Configuration
Command Usage
This command is used in conjunction with the upgrade opcode auto command
to facilitate automatic upgrade of new operational code stored at the location
indicated by this command.
The name for the new image stored on the TFTP server must be ECS2100-
series.bix. However, note that file name is not to be included in this command.

Table of Contents

Other manuals for Edge-Core ECS2100-28T

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS2100-28T and is the answer not in the manual?

Edge-Core ECS2100-28T Specifications

General IconGeneral
ModelECS2100-28T
Switching Capacity56 Gbps
Forwarding Rate41.7 Mpps
MAC Address Table Size16K
Jumbo Frame Support9KB
VLANs4K
Weight3.5 kg
Storage Humidity5% to 95% (non-condensing)
TypeManaged Switch
Ports24 x 10/100/1000BASE-T, 4 x 1G SFP
Power SupplyAC 100-240V, 50/60Hz
Dimensions (W x D x H)440 x 200 x 44 mm
Operating Temperature0 to 50 °C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% (non-condensing)
ManagementSNMP

Related product manuals