| System Management Commands
SMTP Alerts
– 134
logging sendmail host
This command specifies SMTP servers that will be sent alert messages. Use the
no
form to remove an SMTP server.
Syntax
[
no
]
logging sendmail host
ip-address
ip-address - IPv4 address of an SMTP server that will be sent alert messages
for event handling.
Default Setting
None
Command Mode
Global Configuration
Command Usage
You can specify up to three SMTP servers for event handing. However, you must
enter a separate command to specify each server.
To send email alerts, the switch first opens a connection, sends all the email
alerts waiting in the queue one by one, and finally closes the connection.
To open a connection, the switch first selects the server that successfully sent
mail during the last connection, or the first server configured by this command.
If it fails to send mail, the switch selects the next server in the list and tries to
send mail again. If it still fails, the system will repeat the process at a periodic
interval. (A trap will be triggered if the switch cannot successfully open a
connection.)
Example
Console(config)#logging sendmail host 192.168.1.19
Console(config)#
logging sendmail level
This command sets the severity threshold used to trigger alert messages. Use the
no
form to restore the default setting.
Syntax
logging sendmail level
level
no
logging sendmail level
level - One of the system message levels (page 126). Messages sent include
the selected level down to level 0. (Range: 0-7; Default: 7)
Default Setting
Level 7

Table of Contents

Other manuals for Edge-Core ECS2100-28T

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS2100-28T and is the answer not in the manual?

Edge-Core ECS2100-28T Specifications

General IconGeneral
ModelECS2100-28T
Switching Capacity56 Gbps
Forwarding Rate41.7 Mpps
MAC Address Table Size16K
Jumbo Frame Support9KB
VLANs4K
Weight3.5 kg
Storage Humidity5% to 95% (non-condensing)
TypeManaged Switch
Ports24 x 10/100/1000BASE-T, 4 x 1G SFP
Power SupplyAC 100-240V, 50/60Hz
Dimensions (W x D x H)440 x 200 x 44 mm
Operating Temperature0 to 50 °C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% (non-condensing)
ManagementSNMP

Related product manuals