Chapter 4
| System Management Commands
Line
– 122
Example
To specify 2 stop bits, enter this command:
Console(config-line-console)#stopbits 2
Console(config-line-console)#
timeout login
response
This command sets the interval that the system waits for a user to log into the CLI.
Use the
no
form to restore the default setting.
Syntax
timeout login response
[seconds]
no timeout login response
seconds - Integer that specifies the timeout interval.
(Range: 10 - 300 seconds)
Default Setting
300 seconds
Command Mode
Line Configuration
Command Usage
If a login attempt is not detected within the timeout interval, the connection is
terminated for the session.
This command applies to both the local console and Telnet connections.
The timeout for Telnet cannot be disabled.
Using the command without specifying a timeout restores the default setting.
Example
To set the timeout to two minutes, enter this command:
Console(config-line)#timeout login response 120
Console(config-line)#
disconnect
This command terminates an SSH, Telnet, or console connection.
Syntax
disconnect
session-id
session-id – The session identifier for an SSH, Telnet or console connection.