EasyManua.ls Logo

Edge-Core ECS2100-28T Reference Guide

Edge-Core ECS2100-28T
725 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
Chapter 4
| System Management Commands
Event Logging
– 126
Example
Console(config)#logging facility 19
Console(config)#
logging facility
This command sets the facility type for remote logging of syslog messages. Use the
no
form to return the type to the default.
Syntax
logging facility
type
no logging facility
type - A number that indicates the facility used by the syslog server to
dispatch log messages to an appropriate service. (Range: 16-23)
Default Setting
23
Command Mode
Global Configuration
Command Usage
The command specifies the facility type tag sent in syslog messages. (See RFC
3164.) This type has no effect on the kind of messages reported by the switch.
However, it may be used by the syslog server to sort messages or to store messages
in the corresponding database.
Example
Console(config)#logging facility 19
Console(config)#
logging history
This command limits syslog messages saved to switch memory based on severity.
The
no
form returns the logging of syslog messages to the default level.
Syntax
logging history
{
flash
|
ram
}
level
no logging history
{
flash
|
ram
}
flash
- Event history stored in flash memory (i.e., permanent memory).
ram
- Event history stored in temporary RAM (i.e., memory flushed on
power reset).
level - One of the levels listed below. Messages sent include the selected
level down to level 0. (Range: 0-7)

Table of Contents

Other manuals for Edge-Core ECS2100-28T

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS2100-28T and is the answer not in the manual?

Edge-Core ECS2100-28T Specifications

General IconGeneral
ModelECS2100-28T
Switching Capacity56 Gbps
Forwarding Rate41.7 Mpps
MAC Address Table Size16K
Jumbo Frame Support9KB
VLANs4K
Weight3.5 kg
Storage Humidity5% to 95% (non-condensing)
TypeManaged Switch
Ports24 x 10/100/1000BASE-T, 4 x 1G SFP
Power SupplyAC 100-240V, 50/60Hz
Dimensions (W x D x H)440 x 200 x 44 mm
Operating Temperature0 to 50 °C
Storage Temperature-40°C to 70°C
Operating Humidity10% to 90% (non-condensing)
ManagementSNMP

Related product manuals