EasyManuals Logo

Edge-Core ECS2100-28T Reference Guide

Edge-Core ECS2100-28T
725 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #165 background imageLoading...
Page #165 background image
Chapter 5
| SNMP Commands
SNMP Target Host Commands
– 165 –
notifications are enabled. If you enter the command with a keyword, only the
notification type related to that keyword is enabled.
â—†
The
snmp-server enable traps
command is used in conjunction with the
snmp-server host command. Use the snmp-server host command to specify
which host or hosts receive SNMP notifications. In order to send notifications,
you must configure at least one snmp-server host command.
â—†
The authentication traps are legacy notifications, and therefore when used for
SNMP Version 3 hosts, they must be enabled in conjunction with the
corresponding entries in the Notify View assigned by the snmp-server group
command.
Example
Console(config)#snmp-server enable traps authentication
Console(config)#
Related Commands
snmp-server host (165)
snmp-server host
This command specifies the recipient of a Simple Network Management Protocol
notification operation. Use the
no
form to remove the specified host.
Syntax
snmp-server host
host-addr [
inform
[
retry
retries |
timeout
seconds]]
community-string [
version
{
1
|
2c
|
3
{
auth
|
noauth
|
priv
} [
udp-port
port]}
no snmp-server host
host-addr
host-addr - IPv4 or IPv6 address of the host (the targeted recipient).
(Maximum host addresses: 5 trap destination IP address entries)
inform
- Notifications are sent as inform messages. Note that this option is
only available for version 2c and 3 hosts. (Default: traps are used)
retries - The maximum number of times to resend an inform message if
the recipient does not acknowledge receipt. (Range: 0-255; Default: 3)
seconds - The number of seconds to wait for an acknowledgment
before resending an inform message. (Range: 0-2147483647
centiseconds; Default: 1500 centiseconds)
community-string - Password-like community string sent with the
notification operation to SNMP V1 and V2c hosts. Although you can set this
string using the
snmp-server host
command by itself, we recommend
defining it with the snmp-server community command prior to using the
snmp-server host
command. (Maximum length: 32 characters)

Table of Contents

Other manuals for Edge-Core ECS2100-28T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS2100-28T and is the answer not in the manual?

Edge-Core ECS2100-28T Specifications

General IconGeneral
BrandEdge-Core
ModelECS2100-28T
CategorySwitch
LanguageEnglish

Related product manuals