Chapter 11
| Interface Commands
Transceiver Threshold Configuration
– 367 –
Example
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-monitor
Console#
transceiver-threshold-
auto
This command uses default threshold settings obtained from the transceiver to
determine when an alarm or warning message should be sent. Use the
no
form to
disable this feature.
Syntax
transceiver-threshold-auto
Default Setting
Enabled
Command Mode
Interface Configuration (SFP/SFP+ Ports)
Example
Console(config)interface ethernet 1/1
Console(config-if)#transceiver-threshold-auto
Console#
transceiver-threshold
current
This command sets thresholds for transceiver current which can be used to trigger
an alarm or warning message.
Syntax
transceiver-threshold current
{
high-alarm
|
high-warning
|
low-alarm
|
low-warning
} threshold-value
high-alarm
– Sets the high current threshold for an alarm message.
high-warning
– Sets the high current threshold for a warning message.
low-alarm
– Sets the low current threshold for an alarm message.
low-warning
– Sets the low current threshold for a warning message.
threshold-value – The threshold of the transceiver current.
(Range: 0-13100 in units of 0.01 mA)
Default Setting
High Alarm: 100 mA
HIgh Warning: 90 mA
Low Warning: 7 mA
Low Alarm: 6 mA