65 | ES891.x ECU and Bus Interface Module
ETAS ES800 System | User Guide
- 1 FlexRay node with two redundantly usable FlexRay channels
• BOSCH E-Ray-based FlexRay communication controller, compatible with
the FlexRay protocol specification V2.1
• Support of future FlexRay versions through firmware update
• Configuration of the FlexRay node in the application software, e.g., in
INCA, by importing the Fibex file
- Function of the FlexRay interface can be reconfigured in the web interface
to 2 CAN interfaces
- Electrical isolation of the channels from each other, from device ground and
from the supply voltage
Complete technical data for the ES891.x module can be found in chapter “Techni-
cal Data” on page 140.