16 | Safety Information
ETAS ES800 System | User Guide
1.3.2 Operation
Only operate the product with the latest firmware. You can find information about
updating the firmware in the user manual.
If the firmware update is not completed successfully, try it again. If a new firmware
update is not possible and the product is not functional, send the product to ETAS.
Only operate the modules of the system with the protective flap closed.
ES820.1
Only operate the module with the memory module inserted or the memory slot
cover attached.
1.3.3 Electrical Connection
Electrical Safety and Power Supply
- Only connect the product to electric circuits with safety extra-low voltage in
accordance with IEC 61140 (devices of class III) within the voltage limits for
accessible parts as per IEC 61010-1.
- Comply with the connection and setting values (see “Technical Data” on
page 140).
- The power supply for the product must be safely disconnected from the
mains power. For example, use a car battery or a suitable lab power supply.
- Only use lab power supplies with dual protection for the supply network
(with double/reinforced insulation (DI/RI)).
WARNING
Risk due to undefined vehicle behavior during an ECU reset
If you operate the product in combination with ETKs, the ECU must not be reset
in an uncontrolled manner.
- Only make changes when the vehicle is stationary (e.g., changes to the test
setup, changes to the ETK configuration, software updates).
- If you are using the Drive Recorder ES820.1, wait until its MEAS LED is lit con
-
tinuously before driving.
WARNING
Risk due to undefined system behavior when disconnecting the transparent
automotive Ethernet communication between ES886.1/ES886.2 and the ECU
The ES886.1/ES886.2 must not be disconnected from the operating voltage
during an active transparent automotive Ethernet connection.
CAUTION
Risk of burns upon contact with hot surfaces of the SSD memory module
Only touch the SSD memory module by the two push and twist closures.

Table of Contents