46 | ES820.1 Drive Recorder
ETAS ES800 System | User Guide
"Shutdown" Events (change from "Fast boot standby" to "Low
power standby")
Reconfiguration
5.5.6 Available Timers
Configurable timers can be used to delay events that are to trigger the ES820.1 to
change operating state. If necessary, a new hibernation file is generated.
Shutdown\Standby Delay Timer
In the configuration program, the counter can be used to define the amount of
time by which all events that trigger the ES820.1 to change operating state are
delayed. Press the "Power" button on the module and specific events of the INCA
experiment are not influenced or delayed by this timer.
Fast Boot to Shutdown Timer
In the configuration program, the counter can be used to define the amount of
time after which the ES820.1 changes from the "Fast boot standby" operating
state to the "Low power standby" operating state. This counter is activated when
changing to the "Fast boot standby" operating state.
Event Abbrevia-
tion
Description
No. in
Fig. 5-5
10 Timer Expiration of the timer
Event Abbrevia-
tion
Description
No. in
Fig. 5-5
14 Change to the module stack (addition or removal of mod-
ules)
15 Saving the system configuration