96 |
ETAS ES800 System | User Guide
- Ethernet Monitoring with an additional internal TAP on the Ethernet layer
(L2) via both interfaces AE1 and AE2 respectively AE3 and AE4.
At the Automotive Ethernet interface and at the GE and the FE interface of the
ES886.x module the Ethernet Monitoring is supported.
- VLAN hardware filter for Ethernet Monitoring
monitoring data on module are filtered before capturing
at least 8 VLAN IDs are supported
filtering configuration is created and loaded to the ES886.x module by
the application tool (e.g. INCA)
The table shows the combinations in which the functions can be used at the inter-
faces FE, GE, AE1, AE2, AE3 and AE4.
Ethernet Monitoring and Interfaces
The Ethernet Monitoring function can be configured for four interfaces at maxi-
mum:
- Ethernet Monitoring can be used either for the FE interface or the AE1 inter-
face
- Ethernet Monitoring can be used either for the GE interface or the AE2 inter-
face
12.5.3 TAP Function (ES886.x)
The ES886.x modules support the transport of Ethernet frames at the Automotive
Ethernet interfaces AE1-4.
In the TAP-mode, the ES886.x, interrupts the existing Automotive Ethernet line
and transmit the Ethernet Frames unchanged.
This functionality is referred to here as TAP. TAP is used differently in other envi-
ronments.
Nb. FE GE AE1 AE2 AE3 AE4
1 - - BR_XETK BR_XETK BR_XETK - (ES886.1)/
BR_XETK
(ES886.2)
2 - - BR_XETK BR_XETK ETH-Mon ETH-Mon
3 - - BR_XETK BR_XETK TAP-AE3/4 TAP-AE3/4
4 - - TAP-AE1/2 TAP-AE1/2 TAP-AE3/4 TAP-AE3/4
5 - - TAP-AE1/2 TAP-AE1/2 ETH-Mon ETH-Mon
6 - - ETH-Mon ETH-Mon ETH-Mon ETH-Mon
7 ETH-Mon ETH-Mon BR_XETK BR_XETK ETH-Mon ETH-Mon
8 ETH-Mon ETH-Mon BR_XETK BR_XETK TAP-AE3/4 TAP-AE3/4
9 ETH-Mon - BR_XETK ETH-Mon ETH-Mon ETH-Mon
10 - ETH-Mon ETH-Mon BR_XETK ETH-Mon ETH-Mon
ETH Mon: Ethernet Monitoring (Capturing)
TAP-AE1/AE2: internal TAP via both interfaces AE1 and AE2
TAP-AE3/AE4: internal TAP via both interfaces AE3 and AE4